Surgical Interventions & Implants

Shoulder implant strategies and rTSA indications, focusing on component positioning to mitigate scapular notching, loosening, and glenoid bone loss.

Overview

Anatomic total shoulder arthroplasty requires cautious selection of Trabecular Metal–backed glenoid components, with patients requiring close follow-up [1]. Implant survivorship in these procedures is influenced by patient-specific variables, modifiable lifestyle factors, and surgical technique [10]. In contrast, reverse shoulder arthroplasty designs demonstrate robust performance in primary osteoarthritis with no implant-related complications noted across three different systems [2]. Primary reverse shoulder arthroplasty in morbidly obese patients yields good implant survival, reasonable complication rates, and excellent pain relief at intermediate follow-up [3].

For specific anatomical challenges, reaming the glenoid flat for reverse total shoulder arthroplasty without bone-grafting in osteoarthritis patients with an intact rotator cuff produces excellent prosthetic survival with clinical results maintained at a minimum 5-year follow-up [35]. Inset glenoid implants can be safely and effectively used to reconstruct deficient bone where standard implants are contraindicated [16]. Transosseous repair with a cortical implant for greater tubercle cyst-related rotator cuff tears results in satisfactory recovery and clinical outcomes in the short to medium term with low failure rates [4]. Conversely, stemless nano-reverse shoulder arthroplasty is associated with high rates of implant-associated complications and revision compared with literature reports [6].

Surgical costs for total shoulder arthroplasty vary based on implant type, indication, patient comorbidities, and hospital factors [15]. Nonmodified factors driving increased costs include younger age and less common indications for surgery [18]. Potentially modifiable cost drivers include the intraoperative use of a bone graft, implant brand, and reverse total shoulder arthroplasty use [18]. Regarding clavicle fractures, coracoclavicular stabilization using a suture button device for Neer type IIB fractures offers the major advantage that implant removal is not required [11], though reoperation rates for clavicle fracture surgical treatment generally exceed 20%, with the vast majority of reoperations performed for device removal [37].

Anatomy & Pathophysiology

Osseous Morphology and Glenoid Kinematics

Posterior acromial morphology, specifically a more horizontal and higher position of the acromion in the sagittal plane, is significantly associated with posterior shoulder instability [57]. Abnormal glenoid morphology has a significant effect on anatomical and surgical factors, which can necessitate adjustments in surgical technique for reverse shoulder arthroplasty [55]. Downward inclination of the glenoid component restores glenohumeral kinematics in total shoulder arthroplasty [56] but significantly increases cement stress due to subchondral bone resection [56]. In reverse total shoulder arthroplasty, higher glenosphere center-of-rotation offsets lead to an increase in motion in all planes [60].

Center of Rotation and Shear Mechanics

Shear forces are significantly higher when the glenoid component is positioned in the medial center of rotation (MCP) compared with the inferior center of rotation (ICP) [49], with these increased shear forces being more pronounced in early abduction [49]. Nonlateralized reverse total shoulder arthroplasty designs minimize shear forces [52], whereas lateralized reverse total shoulder arthroplasty designs decrease impingement and scapular notching [52]. Reverse shoulder arthroplasty offers favorable biomechanics and proven success for treating older patients with B2 glenoid deformities [32]. Increasing humeral component retroversion in reverse total shoulder arthroplasty does not affect the muscle force requirements for scaption across the shoulder [38].

Soft Tissue Biomechanics and Reconstruction

Following a Latarjet procedure, both the coracobrachialis and short head of biceps exhibit increased extension and internal rotation moment arms at higher degrees of elevation compared with native shoulders [28]. Anatomically, the pectoralis minor tendon provides sufficient tissue length, excursion, and width for acromioclavicular joint reconstruction [39] and is biomechanically as strong as the coracoacromial ligament [39]. Reviews discuss subscapularis pathoanatomy, different techniques for releasing and repairing the tendon, and report biomechanical and clinical outcomes for each technique after total shoulder arthroplasty [63]. Both open and arthroscopic repair of anterosuperior rotator cuff tears with subscapularis involvement significantly improve shoulder function [51] and are relatively safe procedures [51]. Laboratory studies demonstrate improved biomechanics with bursal acromial resurfacing, though there is no consensus on indications, technique, or graft type [44], and clinical results for this procedure remain lacking [44].

Implant Planning and Biomechanical Constraints

Contralateral preoperative templating provides an algorithmic framework for reproducible outcomes in fracture reverse total shoulder arthroplasty [48]. All movement planes show significant differences in simulated range of motion when comparing protocols with and without adjustment for posture in reverse total shoulder arthroplasty preoperative planning [65]. Finite element analysis provides a biomechanical basis to guide the clinical treatment of scapular body fractures using a minimally invasive approach combined with a novel anatomical locking plate [66]. Successful application of suture anchors and tacks in shoulder surgery requires understanding the biology and biomechanics affecting their use [53] and knowledge of factors that can affect subsequent clinical outcomes [53]. The debate regarding the optimum insertion angle for rotator cuff suture anchors continues due to divergent biomechanical studies and confusing geometries [58]. Clinically based conclusions regarding the biomechanical advantages of triple-loaded suture anchors cannot be drawn until clinical information is available [64].

Classification

CRDL: The CRDL classification serves as a reliable and clinically relevant system specifically for evaluating coracoid graft resorption [41].

Nerot-Sirveaux: The validity and reliability of the Nerot-Sirveaux classification system for scapular notching have not been well established [72]. Furthermore, the clinical relevance of scapular notching remains widely unknown [72].

Other Considerations: Instability after reverse shoulder arthroplasty can be successfully treated with revision surgery using a reliable treatment-guiding classification scheme [45]. Correlation of glenoid and humeral component position measurements with clinical outcome, anatomic factors, prosthetic design, and surgical factors will allow for better understanding of the causes of implant failure [7]. Biomechanical analysis of knotless suture anchor systems can demonstrate trends among implants in an experimental setting [70]. Many cleared modern shoulder arthroplasty devices claim predicates based on subsequently recalled prostheses [19]. Long-term outcome studies for many implant designs in anatomic total shoulder replacement remain poorly available [13]. Observed differences in knee scores between different study groups that have not been matched for various clinically relevant factors are at least as likely to represent differences in the patient populations as they are to represent differences in the operative technique or the design of the implant [47].

Clinical Presentation

Implant Selection and Survivorship: Trabecular Metal–backed glenoid components in anatomic total shoulder arthroplasty should be used with caution and patients followed closely [1]. Conversely, no implant-related complications were noted in three different reverse shoulder arthroplasty designs for patients with primary osteoarthritis [2]. Primary reverse shoulder arthroplasty in patients with morbid obesity demonstrates good implant survival, a reasonable complication rate, and excellent pain relief at intermediate follow-up [3]. However, stemless nano-reverse shoulder arthroplasty has high rates of implant-associated complications and revision compared with those reported in the literature [6]. Factors affecting implant survivorship in anatomic total shoulder arthroplasty include patient-specific variables, modifiable lifestyle factors, and surgical technique [10].

Stemless and Custom Component Outcomes: Radiologic evidence of maintained implant stability and good primary fixation exists for a new stemless shoulder prosthesis at 3 years of follow-up [5]. In early fixation of the humeral component in stemless total shoulder arthroplasty, 20 out of 24 implants stabilized within 12 months postoperatively [25], though the significance of continuous migration in four implants remains unclear [25]. Clinical and radiographic outcomes at 2 years for eccentric glenoid reaming in anatomical total shoulder arthroplasty using 3D planning and PSI were promising, highlighting significant patient functional recovery and good implant stability [8]. Prolonged time greater than 6 months from CT scan to device implantation for custom glenoid components in reverse total shoulder arthroplasty resulted in bone loss that rendered the implants unusable [9].

Revision and Complex Reconstruction: Complications are common in revision of failed hemiarthroplasty and anatomic total shoulder arthroplasty to reverse total shoulder arthroplasty and can compromise results [21]. Recognition and management of altered glenoid morphology and diminished bone stock are important for successful shoulder arthroplasty [22]. Transosseous repair with a cortical implant for greater tubercle cyst-related rotator cuff tears results in satisfactory recovery and clinical outcomes in the short to medium term with low failure rates [4]. The major advantage of coracoclavicular stabilization using a suture button device for Neer type IIB lateral clavicle fractures is that implant removal is not required [11].

Diagnostic and Planning Considerations: Correlation of 3-dimensional measurements of glenoid and humeral component position with clinical outcome, anatomic factors, prosthetic design, and surgical factors will allow for better understanding of the causes of implant failure [7]. Pan labral tears can be challenging to diagnose pre-operatively and may result in poor outcomes [24]. Knowledge of the array of shoulder prostheses currently available, the indications for each, and the use of treatment algorithms can lead to optimized patient outcomes [23]. Technologic advances in implant materials, design, amputee care, and imaging continue to drive improvements in patient care and outcomes [14].

Specific Implant Behaviors: The Trabecular Metal Monoblock Acetabular Cup System showed excellent early clinical and radiographic behavior [12].

Investigations

Plain radiography: Radiographic evaluation is critical for assessing implant stability and fixation. Radiologic evidence confirms maintained implant stability and good primary fixation at 3 years for a new stemless shoulder prosthesis [5]. In anatomic total shoulder arthroplasty, clinical and radiographic outcomes at 2 years for eccentric glenoid reaming using 3D planning and patient-specific instrumentation (PSI) highlight significant functional recovery and good implant stability [8]. At an intermediate follow-up of approximately 4 years, no significant differences exist in radiographic or clinical performance between pegged and keeled glenoid components [67]. Radiolucent lines are most commonly observed around the inferior pegs of an all-polyethylene pegged bone-ingrowth glenoid component, potentially representing an incipient mode of failure [71]. Conversely, more bone present between the central peg's radial fins of a partially cemented pegged all-poly glenoid component imparts fewer overall component radiolucencies [50]. Proximal humeral bone resorption after total shoulder arthroplasty with an uncemented rectangular stem is a radiographic phenomenon without significant functional impairment or need for revision within 5 years [46]. In reverse total shoulder arthroplasty for primary osteoarthritis, no implant-related complications were noted across three different designs [2]. Cemented and uncemented reverse total shoulder arthroplasty for primary proximal humerus fractures in the elderly show very satisfying functional outcomes and low revision rates at 2 years, with differences primarily being radiographic findings [69]. Routine radiographic follow-up is recommended after metallic anchor use in arthroscopic rotator cuff repair to identify early failure by anchor pullout [76].

MRI: Magnetic resonance imaging indicates that the donor site after autologous osteochondral mosaicplasty for cartilaginous lesions of the elbow joint is resurfaced with fibrous tissue [59].

CT: Prolonged time greater than 6 months from CT scan to device implantation for custom glenoid components in reverse total shoulder arthroplasty results in bone loss that renders the implants unusable [9].

Other Considerations: Trabecular Metal–backed glenoid components in anatomic total shoulder arthroplasty should be used with caution, requiring close patient follow-up [1]. The Trabecular Metal Monoblock Acetabular Cup System demonstrates excellent early clinical and radiographic behavior [12]. Technologic advances in implant materials, design, amputee care, and imaging continue to drive improvements in patient care and outcomes [14]. The use of a convertible prosthetic system to revise a failed anatomical shoulder arthroplasty reduces morbidity and minimizes the rate of complications [17]. Risk of humeral implant subsidence in Easytech stemless reverse total shoulder arthroplasty is mainly associated with surgical technique and patient activity [20]; despite radiographic subsidence, clinical outcomes remain unaffected, suggesting mild early subsidence may represent a benign self-stabilization process [20]. Integration of bone graft occurs effectively in patients undergoing standard reversed shoulder arthroplasty or bony increased offset, with no relevant changes observed on radiographic evaluation [73]. Excellent functional and radiographic outcomes can be achieved with a modified Weaver-Dunn technique using transosseous bone tunnels and coracoid suture augmentation [74]. Future investigations should continue to research the long-term clinical and radiographic outcomes of hybrid fixation in anatomic shoulder arthroplasty [68].

Treatment

Operative

Indications: Surgical intervention is appropriate for patients with primary osteoarthritis, morbid obesity, or severe posterior glenoid wear, provided the surgeon understands that patient-specific variables and modifiable lifestyle factors significantly affect implant survivorship [2, 3, 10, 42]. While long-term outcome studies for many implant designs remain poorly available despite advances in biomechanics and tribology, specific indications include greater tubercle cyst-related rotator cuff tears and Neer type IIB lateral clavicle fractures [4, 11, 13].

Surgical Approach / Technique: For anatomical total shoulder arthroplasty, eccentric glenoid reaming using 3D planning and patient-specific instrumentation (PSI) yields promising clinical and radiographic outcomes at 2 years, though no significant differences exist between PSI and standard instrumentation regarding patient-reported outcomes, complication rates, or positioning accuracy [8, 40]. Posterior glenoid bone grafting provides a biological basis for healing, prevents component penetration, and maintains survivorship in osteoarthritis with severe posterior wear [42]. In cases of deficient bone where standard implants are contraindicated, inset glenoid implants can be safely and effectively utilized [16]. For fractures complicating total shoulder arthroplasty, both nonoperative and operative treatments may be successful [61], while shoulder arthrodesis is best achieved using combined screw/plate fixation to avoid non-union [77].

Implant Selection: Trabecular Metal–backed glenoid components in anatomic total shoulder arthroplasty should be used with caution and patients followed closely [1]. Conversely, no implant-related complications were noted in three different reverse shoulder arthroplasty designs for primary osteoarthritis [2]. A straight short stem system validates efficacy for acceptable clinical outcomes and implant stability in reverse shoulder arthroplasty at mid-term follow-up [33]. However, rates of implant-associated complications and revision are high for a stemless nano-reverse shoulder arthroplasty compared with literature reports [6], whereas radiologic evidence of maintained stability and good primary fixation exists at 3 years for a new stemless shoulder prosthesis [5]. Risk of humeral implant subsidence in Easytech stemless reverse total shoulder arthroplasty is mainly associated with surgical technique and patient activity, yet clinical outcomes remain unaffected despite radiographic subsidence, suggesting mild early subsidence may represent a benign self-stabilization process [20]. Primary reverse shoulder arthroplasty in morbidly obese patients demonstrates good implant survival, a reasonable complication rate, and excellent pain relief at intermediate follow-up [3]. Both glenoid bone grafting and augmented glenoid baseplates in reverse shoulder arthroplasty improve overall clinical outcomes with relatively low complication and revision rates [36]. There is no indication that a platform system is superior to a standard prosthesis regarding revision rates at the implant component level [27]. All-arthroscopic biologic total shoulder resurfacing preserves bone stock, limits damage to surrounding structures, and allows for early rehabilitation, potentially offering superiority over other treatments [78].

Alignment / Balancing Strategy: No specific alignment strategy is supported by the provided evidence beyond the general use of 3D planning and PSI for eccentric glenoid reaming in anatomical total shoulder arthroplasty [8].

Pain Management: No specific analgesia regimens are supported by the provided evidence.

Adjuncts: No specific adjuncts such as tourniquet, tranexamic acid, or drains are supported by the provided evidence.

Revision: Revision principles are informed by the finding that no indication exists that a platform system is better than a standard prosthesis regarding revision rates at the implant component level [27].

Other Considerations: Surgical implant type, indication, patient comorbidities, and hospital factors contribute to differential surgical costs for total shoulder arthroplasty [15]. Nonmodifiable factors associated with increased cost include younger age and less common indications for surgery [18]. Potentially modifiable factors associated with increased cost include the intraoperative use of a bone graft, implant brand, and reverse total shoulder arthroplasty use [18]. The major advantage of coracoclavicular stabilization using a suture button device for Neer type IIB lateral clavicle fractures is that implant removal is not required [11]. Transosseous repair with a cortical implant for greater tubercle cyst-related rotator cuff tear results in satisfactory recovery and clinical outcomes in the short to medium term with low failure rates [4].

Complications

Infection (PJI): The greatest risk factors for periprosthetic infection after reverse shoulder arthroplasty are a history of a prior failed arthroplasty and age younger than 65 years [80]. US veterans with a history of Hepatitis C infection are at an increased risk of developing medical but not surgical complications within the first year after total shoulder arthroplasty [79].

Aseptic loosening: Trabecular Metal–backed glenoid components in anatomic total shoulder arthroplasty should be used with caution and patients followed closely [1]. Stemless nano-reverse shoulder arthroplasty has high rates of implant-associated complications and revision compared with those reported in the literature [6]. Correlation of glenoid and humeral component position measurements with clinical outcome, anatomic factors, prosthetic design, and surgical factors will allow for better understanding of the causes of implant failure [7]. Factors affecting implant survivorship in anatomic total shoulder arthroplasty include patient-specific variables, modifiable lifestyle factors, and surgical technique [10].

Instability: Bipolar radial head arthroplasty is associated with major primary complications and a high incidence of radiographic signs of degenerative changes after 8.8 years [81].

Other Considerations: No implant-related complications were noted in three different reverse shoulder arthroplasty designs for patients with primary osteoarthritis [2]. Primary reverse shoulder arthroplasty in patients with morbid obesity demonstrates good implant survival with a reasonable complication rate at intermediate follow-up [3]. Transosseous repair with a cortical implant for greater tubercle cyst-related rotator cuff tear results in significant implant migration despite satisfactory recovery and clinical outcomes [4]. A new stemless shoulder prosthesis demonstrates radiologic evidence of maintained implant stability and good primary fixation at 3 years of follow-up [5]. Prolonged time greater than 6 months from CT scan to device implantation for custom glenoid components in reverse total shoulder arthroplasty resulted in bone loss that rendered the implants unusable [9]. Many cleared modern shoulder arthroplasty devices claim predicates based on subsequently recalled prostheses [19]. Augmented polyethylene glenoid components demonstrated improved clinical outcomes without implant failure or complications during short-term follow-up in the presence of posterior glenoid bone loss [29]. Further follow-up and a larger series of patients are necessary to determine the long-term outcomes and complications associated with total shoulder arthroplasty using an augmented component for anterior glenoid bone deficiency [34].

Recovery

Light activity (weeks): Evidence does not specify a precise week range for light activity or driving; however, patients undergoing primary reverse shoulder arthroplasty for primary osteoarthritis demonstrated no implant-related complications, suggesting a baseline for early mobilization [2]. Patients 59 years of age and younger face an increased risk of revision at early follow-up, necessitating careful monitoring during this initial phase [83].

Full activity (months): Clinical and radiographic outcomes at 2 years for eccentric glenoid reaming in anatomical total shoulder arthroplasty using 3D planning and patient-specific instrumentation (PSI) highlight significant patient functional recovery [8]. Primary reverse shoulder arthroplasty in patients with morbid obesity demonstrates excellent pain relief and reasonable complication rates at intermediate follow-up, supporting a trajectory toward full activity [3]. At short-term follow-up, no difference in functional outcome exists between two different short press-fit humeral stem designs in total shoulder arthroplasty [30].

Complete recovery / outcome plateau (months): At 3 years of follow-up, a new stemless shoulder prosthesis shows radiologic evidence of maintained implant stability and good primary fixation [5]. Transosseous repair with a cortical implant for greater tubercle cyst-related rotator cuff tear results in satisfactory recovery and clinical outcomes in the short to medium term with low failure rates [4]. Continuous loop double endobutton reconstruction for acromioclavicular joint dislocation yielded excellent results that were maintained over long-term follow-up [31]. Long-term outcome studies for many implant designs in anatomic total shoulder replacement remain poorly available despite advances in biomechanics, design, and tribology [13].

Rehabilitation protocol: Trabecular Metal–backed glenoid components in anatomic total shoulder arthroplasty should be used with caution and patients followed closely [1]. Enthusiasm for impaction bone grafting of the glenoid in revision shoulder arthroplasty should be guarded due to a short follow-up period, although results to date justify continued use and follow-up [43]. Prolonged time greater than 6 months from CT scan to device implantation for custom glenoid components in reverse total shoulder arthroplasty resulted in bone loss that rendered the implants unusable, indicating strict timing protocols for preoperative planning [9].

Functional milestones: The Trabecular Metal Monoblock Acetabular Cup System showed excellent early clinical and radiographic behavior, serving as a reference for implant performance [12]. Further studies with long-term follow-up are needed to determine whether the grafted area in autologous matrix-induced chondrogenesis for focal cartilage defects will maintain structural and functional integrity over time [26]. Direct exchange arthroplasty for infection after total hip replacement can yield a rate of success comparable with delayed exchange if antibiotic-loaded cement and appropriate postoperative antibiotics are used [82].

Key Evidence

  • [L4] This implant should be used with caution, and patients followed closely. (10.1016/j.jse.2017.09.036)
  • [L3] In all three groups, no implant related complications were noted. (10.1186/s12891-025-08749-y)
  • [L4] At intermediate follow-up, there is good implant survival with a reasonable complication rate and excellent pain relief. (10.1016/j.jse.2015.12.008)
  • [L3] The ATO method performed with a cortical implant in RCTs resulted in satisfactory recovery and clinical outcomes in the short to medium term with low failure rates. (10.1007/s00167-022-06958-9)
  • [L4] At 3 years of follow-up, there is radiologic evidence of maintained implant stability and good primary fixation. (10.1016/j.jse.2009.12.009)
  • [L4] However, the rates of implant-associated complications and revision are high compared with those reported in the literature. (10.1186/s12891-025-09386-1)
  • [L5] Ultimately, correlation of these measurements with clinical outcome, anatomic factors, prosthetic design, and surgical factors will allow for better understanding of the causes of implant failure. (10.1016/j.jse.2013.01.005)
  • [L4] Clinical and radiographic outcomes at 2 years were promising, highlighting significant patient functional recovery and good implant stability. (10.1016/j.jse.2022.01.010)
  • [L3] Prolonged time (>6 months) from CT scan to device implantation resulted in bone loss that rendered the implants unusable. (10.5397/cise.2023.00563)
  • [L4] Surgeons must understand factors affecting implant survivorship, including patient-specific variables, modifiable lifestyle factors, and surgical technique, to ensure optimal outcomes. (10.5435/jaaos-d-21-00302)
  • [L4] The major advantage of this technique is that implant removal is not required. (10.1016/j.jse.2016.09.048)
  • [L4] The implant showed excellent early clinical and radiographic behavior. (10.1016/j.arth.2008.09.027)
  • [L5] Advances in biomechanics, design, and tribology have improved understanding, but long-term outcome studies for many implant designs remain poorly available. (10.1177/1758573218790119)
  • [L3] Surgical implant type, indication, patient comorbidities, and hospital factors contribute to differential surgical cost for total shoulder arthroplasty. (10.1016/j.jse.2025.02.055)
  • [L4] This study documents for the first time the possibility of safely and effectively using inset glenoid implants to reconstruct deficient bone for which standard implants are contraindicated. (10.1016/j.jse.2011.03.023)
  • [L4] The use of a convertible prosthetic system to revise a failed anatomical shoulder arthroplasty reduces morbidity and minimises the rate of complications. (10.1302/0301-620x.97b12.35176)
  • [L4] Nonmodified factors associated with increased cost included younger age and less common indications for surgery, whereas potentially modifiable factors included the intraoperative use of a bone graft, implant brand, and RTSA use. (10.1016/j.jse.2018.11.065)
  • [L4] Many of the cleared modern devices claim predicates based on subsequently recalled prostheses. (10.1016/j.jse.2022.09.017)
  • [L3] Despite radiographic subsidence, clinical outcomes remained unaffected, suggesting mild early subsidence may represent a benign self-stabilization process. (10.1016/j.jse.2025.09.003)
  • [L4] As is typical of revision surgery, complications are common and can compromise results. (10.1016/j.jse.2018.10.026)
  • [L5] Recognition and management of altered glenoid morphology and diminished bone stock are important for successful shoulder arthroplasty. (10.5435/jaaos-20-09-604)
  • [L5] Knowledge of the array of shoulder prostheses currently available and the indications for each, as well as the use of treatment algorithms, can lead to optimized patient outcomes. (10.5435/00124635-200907000-00002)
  • [L4] Pan labral tears can be challenging to diagnose pre-operatively and may result in poor outcomes. (10.1177/17585732251316476)
  • [L2] 20 out of 24 implants stabilized within 12 months postoperatively, while the significance of continuous migration in four implants remains unclear. (10.1302/0301-620x.104b1.bjj-2021-0945.r1)
  • [L4] However, further studies with long-term follow-up are needed to determine whether the grafted area will maintain structural and functional integrity over time. (10.1007/s00167-010-1042-3)
  • [L3] No indication that platform system is better than standard prosthesis was found, and the results were equivalent. (10.1016/j.jse.2023.02.107)
  • [L5] Both muscles had increased extension and internal rotation moment arms at higher degrees of elevation compared with the native shoulders. (10.1016/j.jse.2023.10.011)
  • [L4] Augmented polyethylene glenoid components demonstrated improved clinical outcome, without implant failure or complications, during short-term follow-up. (10.1016/j.jse.2016.09.053)
  • [L3] At short-term follow-up, there is no difference in functional outcome or revision between 2 different humeral stem designs. (10.1016/j.jse.2017.08.010)
  • [L4] Excellent results were obtained and maintained over long-term follow-up. (10.1177/0363546515596409)
  • [L5] Reverse shoulder arthroplasty is a useful tool for treating older patients with B2 glenoid deformities, offering favorable biomechanics and proven success. (10.1177/2471549219897661)
  • [L4] This study validates the efficacy of a straight short stem for acceptable clinical outcomes and implant stability in RSA. (10.1016/j.jse.2024.07.035)
  • [L4] Further follow-up and a larger series of patients are necessary to determine the long-term outcomes and complications associated with this technique. (10.1016/j.jse.2015.08.012)
  • [L4] For the studied indication, reaming the glenoid flat produced excellent prosthetic survival with clinical results maintained at a minimum 5-year follow-up. (10.2106/jbjs.20.01042)
  • [L4] Both treatments improve overall clinical outcomes with relatively low complication rates and revision rates. (10.1016/j.jse.2022.11.017)
  • [L3] However, reoperation rates exceed 20%, the vast majority of reoperations being performed for device removal. (10.1186/s12891-022-05075-5)
  • [L5] Increasing retroversion did not affect the muscle force requirements for scaption across the shoulder. (10.1016/j.jse.2011.07.027)
  • [L5] Anatomically, it provides sufficient tissue length, excursion, and width, and biomechanically, it is as strong as the coracoacromial ligament. (10.1016/j.jse.2006.09.007)
  • [L1] This study found no significant differences in patient-reported outcomes, complication rates, or implant positioning accuracy between PSI and SI in primary TSA. (10.5397/cise.2024.01095)
  • [L3] The CRDL classification is a reliable and clinically relevant system for coracoid graft resorption evaluation. (10.1177/03635465251408095)
  • [L4] The procedure provides a biological basis for healing and prevents component penetration while maintaining implant survivorship. (10.1016/j.jse.2017.03.016)
  • [L4] The follow-up period is short, so enthusiasm should be guarded at this stage, although the results to date justify the continued use and follow-up of this technique. (10.1111/j.1758-5740.2009.00017.x)
  • [L5] While laboratory studies demonstrate improved biomechanics with bursal acromial resurfacing, there is no consensus on indications, technique, or graft type, and clinical results remain lacking. (10.1016/j.arthro.2024.07.006)
  • [L4] Instability after RSA can be successfully treated with revision surgery using the reliable treatment-guiding classification scheme presented herein. (10.1016/j.jse.2017.09.031)
  • [L2] This is a radiographic phenomenon without significant impairment of function or need for revision within 5 years after surgery. (10.1016/j.jse.2014.02.024)
  • [L4] Observed differences in knee scores between different study groups that have not been matched for various clinically relevant factors are at least as likely to represent differences in the patient populations as they are to represent differences in the operative technique or the design of the implant. (10.2106/00004623-199706000-00009)
  • [L4] The information obtained from the template provides an algorithmic framework that provides reproducible outcomes for a highly functional and stable shoulder unique to each patient. (10.1016/j.xrrt.2023.05.004)
  • [L5] Shear forces are significantly higher when the glenoid component is positioned in the MCP compared with the ICP, and this is more pronounced in early abduction. (10.1016/j.jse.2014.12.017)
  • [L4] More bone imparted fewer overall component radiolucencies. (10.1016/j.jse.2010.05.025)
  • [L3] Both techniques significantly improved shoulder function and are relatively safe procedures. (10.1016/j.jse.2019.09.035)
  • [L4] The review summarizes biomechanical concepts and clinical outcomes, noting that nonlateralized designs minimize shear forces while lateralized designs decrease impingement and scapular notching. (10.1177/1758573220937412)
  • [L5] Successful application requires understanding the biology and biomechanics affecting use, as well as knowledge of factors that can affect subsequent clinical outcomes. (10.1177/0363546505282621)
  • [L4] Abnormal glenoid morphology was shown to have a significant effect on anatomical and surgical factors which can necessitate adjustments in surgical technique for reverse shoulder arthroplasty. (10.1016/j.jse.2009.02.013)
  • [L5] The downward inclination of the glenoid restored glenohumeral kinematics but significantly increased cement stress due to subchondral bone resection. (10.1016/j.jse.2008.11.008)
  • [L3] Posterior acromial morphology, specifically a more horizontal and higher position of the acromion in the sagittal plane, is significantly associated with posterior shoulder instability. (10.2106/jbjs.18.00541)
  • [L5] The debate regarding the optimum insertion angle for rotator cuff suture anchors continues due to divergent biomechanical studies and confusing geometries; the authors suggest that all research is bringing the field closer to scientific truth and highlight the need for dynamic, human cadaveric models in future analyses. (10.1016/j.arthro.2014.10.002)
  • [L4] However, magnetic resonance imaging indicates that the donor site is resurfaced with fibrous tissue. (10.1177/0363546507306465)
  • [L5] Higher glenosphere center-of-rotation offsets led to an increase in motion in all planes. (10.1016/j.jse.2012.02.004)
  • [L4] Both nonoperative and operative treatment may be successful in the treatment of fractures complicating total shoulder arthroplasty. (10.1016/j.jse.2007.05.007)
  • [L5] This review discusses the subscapularis pathoanatomy, different techniques for releasing and repairing the tendon, and reports biomechanical and clinical outcomes for each technique after total shoulder arthroplasty. (10.1016/j.jse.2016.11.006)
  • [Letter] This is a biomechanical bench test and clinically based conclusions cannot be drawn until clinical information is available. (10.1016/j.arthro.2010.05.009)
  • [L4] All movement planes showed significant differences in simulated range of motion when comparing protocols with and without adjustment for posture. (10.1302/0301-620x.106b11.bjj-2024-0110.r1)
  • [L5] The study provided a biomechanical basis to guide the clinical treatment of scapular body fractures. (10.1186/s13018-024-04905-7)
  • [L3] At an intermediate follow-up period of approximately 4 years, there were no significant differences in either radiographic or clinical performance between the pegged and keeled designs. (10.1016/j.jse.2009.10.018)
  • [L5] Future investigations should continue to research the long-term clinical and radiographic outcomes of this fixation method. (10.1016/j.xrrt.2021.01.005)
  • [L3] However, this was primarily a radiographic finding as both groups showed very satisfying functional outcomes and low revision rates at the 2-year follow-up. (10.1186/s12891-022-05994-3)
  • [L5] Biomechanical analysis of knotless suture anchor systems can demonstrate trends among implants in an experimental setting. (10.1016/j.jse.2007.05.016)
  • [L4] Radiolucent lines were seen most commonly around the inferior pegs of the prosthesis, and this may represent an incipient mode of failure. (10.2106/jbjs.15.00475)
  • [L5] However, the clinical relevance of scapular notching remains widely unknown, and the validity and reliability of the classification system have not been well established. (10.1097/corr.0000000000000442)
  • [L3] Integration of the bone graft occurs effectively, with no relevant changes observed on radiographic evaluation. (10.5397/cise.2022.01270)
  • [L4] Excellent functional and radiographic outcomes can be achieved with this modified Weaver-Dunn technique. (10.5435/jaaos-d-21-00732)
  • [L3] We recommend routine radiographic follow-up after use of metallic anchors to ensure identification of early failure by anchor pullout. (10.1016/j.arthro.2009.08.015)
  • [L3] A combined screw/plate fixation offers the best option for avoiding non-union of the arthrodesis. (10.1111/j.1758-5740.2011.00174.x)
  • [L4] The technique has the potential to be superior to other available treatments because it preserves bone stock, limits damage to surrounding structures, and allows for early rehabilitation. (10.1016/j.arthro.2011.07.008)
  • [L3] US veterans with a history of HCV are at an increased risk of developing medical but not surgical complications within the first year after TSA. (10.1016/j.jseint.2021.02.009)
  • [L3] The greatest risk factors for infection after RSA were history of a prior failed arthroplasty and age younger than 65 years. (10.1016/j.jse.2014.05.020)
  • [L4] Despite major primary complications and high incidence of radiographic signs of degenerative changes after 8.8 years, mainly good clinical results were achieved with Judet's bipolar prosthesis. (10.1016/j.jse.2010.05.022)
  • [L4] The experience suggests that direct exchange can yield a rate of success comparable with that of delayed exchange if antibiotic-loaded cement and appropriate postoperative antibiotics are used. (10.2106/00004623-199807000-00004)
  • [L3] This study suggests patients 59 years and younger have an increased risk of revision at early follow-up. (10.1016/j.jse.2013.01.029)

See Also

References

[1] Outcomes of Trabecular Metal–backed glenoid components in anatomic total shoulder arthroplasty. Journal of Shoulder and Elbow Surgery. 2018. DOI: 10.1016/j.jse.2017.09.036

[2] Clinical and radiological comparison of three different reverse shoulder arthroplasty designs for patients with primary osteoarthritis. BMC Musculoskeletal Disorders. 2025. DOI: 10.1186/s12891-025-08749-y

[3] Outcomes of primary reverse shoulder arthroplasty in patients with morbid obesity. Journal of Shoulder and Elbow Surgery. 2016. DOI: 10.1016/j.jse.2015.12.008

[4] Transosseous repair with a cortical implant for greater tubercle cyst‐related rotator cuff tear results in good clinical outcomes, but significant implant migration. Knee Surgery, Sports Traumatology, Arthroscopy. 2022. DOI: 10.1007/s00167-022-06958-9

[5] Results of a new stemless shoulder prosthesis: Radiologic proof of maintained fixation and stability after a minimum of three years' follow-up. Journal of Shoulder and Elbow Surgery. 2010. DOI: 10.1016/j.jse.2009.12.009

[6] Long-term clinical and radiological outcomes of a stemless reverse shoulder implant that is fallen out of favor - stemless nano-reverse shoulder arthroplasty. BMC Musculoskeletal Disorders. 2026. DOI: 10.1186/s12891-025-09386-1

[7] Development and validation of a new method of 3-dimensional assessment of glenoid and humeral component position after total shoulder arthroplasty. Journal of Shoulder and Elbow Surgery. 2013. DOI: 10.1016/j.jse.2013.01.005

[8] Clinical And Radiographic Results Of Eccentric Glenoid Reaming In Anatomical Total Shoulder Arthroplasty Using 3D Planning And PSI. Journal of Shoulder and Elbow Surgery. 2022. DOI: 10.1016/j.jse.2022.01.010

[9] Use of custom glenoid components for reverse total shoulder arthroplasty. Clinics in Shoulder and Elbow. 2023. DOI: 10.5397/cise.2023.00563

[10] Survivorship of Anatomic Total Shoulder Arthroplasty. Journal of the American Academy of Orthopaedic Surgeons. 2022. DOI: 10.5435/jaaos-d-21-00302

[11] Coracoclavicular stabilization using a suture button device for Neer type IIB lateral clavicle fractures. Journal of Shoulder and Elbow Surgery. 2017. DOI: 10.1016/j.jse.2016.09.048

[12] Migration of the Trabecular Metal Monoblock Acetabular Cup System. The Journal of Arthroplasty. 2010. DOI: 10.1016/j.arth.2008.09.027

[13] Journey of the glenoid in anatomic total shoulder replacement. Shoulder & Elbow. 2018. DOI: 10.1177/1758573218790119

[14] Chapter 3 Emerging Technologies in Orthopaedic Trauma. 2021.

[15] Same reimbursement, different cost: risk factors for high-cost total shoulder arthroplasty. Journal of Shoulder and Elbow Surgery. 2025. DOI: 10.1016/j.jse.2025.02.055

[16] Total shoulder replacement surgery with custom glenoid implants for severe bone deficiency. Journal of Shoulder and Elbow Surgery. 2012. DOI: 10.1016/j.jse.2011.03.023

[17] The use of a modular system to convert an anatomical total shoulder arthroplasty to a reverse shoulder arthroplasty. The Bone & Joint Journal. 2015. DOI: 10.1302/0301-620x.97b12.35176

[18] An analysis of costs associated with shoulder arthroplasty. Journal of Shoulder and Elbow Surgery. 2019. DOI: 10.1016/j.jse.2018.11.065

[19] Shoulder arthroplasty device clearance: an ancestral network analysis. Journal of Shoulder and Elbow Surgery. 2023. DOI: 10.1016/j.jse.2022.09.017

[20] Risk of humeral implant subsidence in Easytech stemless rTSA is mainly associated with surgical technique and patient activity. Journal of Shoulder and Elbow Surgery. 2026. DOI: 10.1016/j.jse.2025.09.003

[21] Revision of failed hemiarthroplasty and anatomic total shoulder arthroplasty to reverse total shoulder arthroplasty. Journal of Shoulder and Elbow Surgery. 2019. DOI: 10.1016/j.jse.2018.10.026

[22] Glenoid Bone Loss in Primary Total Shoulder Arthroplasty: Evaluation and Management. Journal of the American Academy of Orthopaedic Surgeons. 2012. DOI: 10.5435/jaaos-20-09-604

[23] Shoulder Arthroplasty: Prosthetic Options and Indications. Journal of the American Academy of Orthopaedic Surgeons. 2009. DOI: 10.5435/00124635-200907000-00002

[24] Traumatic 270° and 360° labral tears of shoulder – Injury patterns, surgical technique, and mid-term outcomes. Shoulder & Elbow. 2025. DOI: 10.1177/17585732251316476

[25] Early fixation of the humeral component in stemless total shoulder arthroplasty. The Bone & Joint Journal. 2022. DOI: 10.1302/0301-620x.104b1.bjj-2021-0945.r1

[26] Mid‐term results of Autologous Matrix‐Induced Chondrogenesis for treatment of focal cartilage defects in the knee. Knee Surgery, Sports Traumatology, Arthroscopy. 2010. DOI: 10.1007/s00167-010-1042-3

[27] Revision Rate Of Shoulder Arthroplasty On Implant Component Level In Platform System Compared To Standard Design. Journal of Shoulder and Elbow Surgery. 2023. DOI: 10.1016/j.jse.2023.02.107

[28] Moment arms of the coracobrachialis and short head of biceps following a Latarjet procedure: a modeling study. Journal of Shoulder and Elbow Surgery. 2024. DOI: 10.1016/j.jse.2023.10.011

[29] Radiographic results of augmented all-polyethylene glenoids in the presence of posterior glenoid bone loss during total shoulder arthroplasty. Journal of Shoulder and Elbow Surgery. 2017. DOI: 10.1016/j.jse.2016.09.053

[30] Radiographic changes differ between two different short press-fit humeral stem designs in total shoulder arthroplasty. Journal of Shoulder and Elbow Surgery. 2018. DOI: 10.1016/j.jse.2017.08.010

[31] Continuous Loop Double Endobutton Reconstruction for Acromioclavicular Joint Dislocation. The American Journal of Sports Medicine. 2015. DOI: 10.1177/0363546515596409

[32] Reverse Shoulder Arthroplasty for B2 Glenoid Deformity. Journal of Shoulder and Elbow Arthroplasty. 2019. DOI: 10.1177/2471549219897661

[33] Assessing the efficacy: mid-term clinical and radiological outcomes of the comprehensive short stem system in reverse shoulder arthroplasty. Journal of Shoulder and Elbow Surgery. 2025. DOI: 10.1016/j.jse.2024.07.035

[34] Total shoulder arthroplasty with an augmented component for anterior glenoid bone deficiency. Journal of Shoulder and Elbow Surgery. 2016. DOI: 10.1016/j.jse.2015.08.012

[35] Reverse Total Shoulder Arthroplasty without Bone-Grafting for Severe Glenoid Bone Loss in Patients with Osteoarthritis and Intact Rotator Cuff. Journal of Bone and Joint Surgery. 2021. DOI: 10.2106/jbjs.20.01042

[36] Comparison of glenoid bone grafting vs. augmented glenoid baseplates in reverse shoulder arthroplasty: a systematic review. Journal of Shoulder and Elbow Surgery. 2023. DOI: 10.1016/j.jse.2022.11.017

[37] Surgical treatment, complications, reoperations, and healthcare costs among patients with clavicle fracture in England. BMC Musculoskeletal Disorders. 2022. DOI: 10.1186/s12891-022-05075-5

[38] Humeral component retroversion in reverse total shoulder arthroplasty: a biomechanical study. Journal of Shoulder and Elbow Surgery. 2012. DOI: 10.1016/j.jse.2011.07.027

[39] Anatomy of the pectoralis minor tendon and its use in acromioclavicular joint reconstruction. Journal of Shoulder and Elbow Surgery. 2007. DOI: 10.1016/j.jse.2006.09.007

[40] Patient-specific instrumentation in primary total shoulder arthroplasty: a meta-analysis of clinical outcomes. Clinics in Shoulder and Elbow. 2025. DOI: 10.5397/cise.2024.01095

[41] Impact of Significant Coracoid Graft Resorption on Clinical Outcomes After Arthroscopic Latarjet Procedure: Development and Validation of a Refined Classification System for Coracoid Bone Graft Resorption. The American Journal of Sports Medicine. 2026. DOI: 10.1177/03635465251408095

[42] Posterior glenoid bone grafting in total shoulder arthroplasty for osteoarthritis with severe posterior glenoid wear. Journal of Shoulder and Elbow Surgery. 2017. DOI: 10.1016/j.jse.2017.03.016

[43] Impaction Bone Grafting of the Glenoid in Revision Shoulder Arthroplasty: Classification, Technical Description and Early Results. Shoulder & Elbow. 2009. DOI: 10.1111/j.1758-5740.2009.00017.x

[44] Editorial Commentary : Bursal Acromial Resurfacing Offers Improved Biomechanics in Laboratory Studies but There Is No Consensus on Indications, Technique, or Graft Type, and Clinical Results Are Lacking. Arthroscopy. 2024. DOI: 10.1016/j.arthro.2024.07.006

[45] Classification of instability after reverse shoulder arthroplasty guides surgical management and outcomes. Journal of Shoulder and Elbow Surgery. 2018. DOI: 10.1016/j.jse.2017.09.031

[46] Patterns of proximal humeral bone resorption after total shoulder arthroplasty with an uncemented rectangular stem. Journal of Shoulder and Elbow Surgery. 2014. DOI: 10.1016/j.jse.2014.02.024

[47] Demographic Biases of Scoring Instruments for the Results of Total Knee Arthroplasty. The Journal of Bone & Joint Surgery*. 1997. DOI: 10.2106/00004623-199706000-00009

[48] Contralateral preoperative templating for fracture reverse total shoulder arthroplasty: technique article and case series. JSES Reviews, Reports, and Techniques. 2023. DOI: 10.1016/j.xrrt.2023.05.004

[49] Rocking-horse phenomenon of the glenoid component: the importance of inclination. Journal of Shoulder and Elbow Surgery. 2015. DOI: 10.1016/j.jse.2014.12.017

[50] Bone presence between the central peg's radial fins of a partially cemented pegged all poly glenoid component suggest few radiolucencies. Journal of Shoulder and Elbow Surgery. 2011. DOI: 10.1016/j.jse.2010.05.025

[51] Retrospective review of open and arthroscopic repair of anterosuperior rotator cuff tears with subscapularis involvement: a single surgeon's experience. Journal of Shoulder and Elbow Surgery. 2020. DOI: 10.1016/j.jse.2019.09.035

[52] Lateralized versus nonlateralized reverse total shoulder arthroplasty. Shoulder & Elbow. 2020. DOI: 10.1177/1758573220937412

[53] Suture Anchors and Tacks for Shoulder Surgery, Part 1. The American Journal of Sports Medicine. 2005. DOI: 10.1177/0363546505282621

[55] Glenoid morphology in reverse shoulder arthroplasty: Classification and surgical implications. Journal of Shoulder and Elbow Surgery. 2009. DOI: 10.1016/j.jse.2009.02.013

[56] Total shoulder arthroplasty: Downward inclination of the glenoid component to balance supraspinatus deficiency. Journal of Shoulder and Elbow Surgery. 2009. DOI: 10.1016/j.jse.2008.11.008

[57] Posterior Acromial Morphology Is Significantly Associated with Posterior Shoulder Instability. Journal of Bone and Joint Surgery. 2019. DOI: 10.2106/jbjs.18.00541

[58] A Cavalcade of Shoulder Controversies: Deadman Angle Revisited… Divergent Anchor Angles and Depths, and Rotator Cuff Vectors Confuse Comparison… and More. Arthroscopy. 2014. DOI: 10.1016/j.arthro.2014.10.002

[59] Donor Site Evaluation after Autologous Osteochondral Mosaicplasty for Cartilaginous Lesions of the Elbow Joint. The American Journal of Sports Medicine. 2007. DOI: 10.1177/0363546507306465

[60] Reverse shoulder arthroplasty components and surgical techniques that restore glenohumeral motion. Journal of Shoulder and Elbow Surgery. 2013. DOI: 10.1016/j.jse.2012.02.004

[61] Treatment of fractures adjacent to humeral prostheses. Journal of Shoulder and Elbow Surgery. 2008. DOI: 10.1016/j.jse.2007.05.007

[63] Management of the subscapularis tendon during total shoulder arthroplasty. Journal of Shoulder and Elbow Surgery. 2017. DOI: 10.1016/j.jse.2016.11.006

[64] Regarding Biomechanical Advantages of Triple‐loaded Suture Anchors. Arthroscopy. 2010. DOI: 10.1016/j.arthro.2010.05.009

[65] SECEC Grammont Award 2024: The critical role of posture adjustment for range of motion simulation in reverse total shoulder arthroplasty preoperative planning. The Bone & Joint Journal. 2024. DOI: 10.1302/0301-620x.106b11.bjj-2024-0110.r1

[66] Finite element analysis of the treatment of a minimally invasive approach combined with a novel anatomical locking plate for scapular body fractures. Journal of Orthopaedic Surgery and Research. 2024. DOI: 10.1186/s13018-024-04905-7

[67] Pegged versus keeled glenoid components in total shoulder arthroplasty. Journal of Shoulder and Elbow Surgery. 2010. DOI: 10.1016/j.jse.2009.10.018

[68] Hybrid fixation in anatomic shoulder arthroplasty: surgical technique and review of the literature. JSES Reviews, Reports, and Techniques. 2021. DOI: 10.1016/j.xrrt.2021.01.005

[69] Cemented vs. uncemented reverse total shoulder arthroplasty for the primary treatment of proximal humerus fractures in the elderly—a retrospective case–control study. BMC Musculoskeletal Disorders. 2022. DOI: 10.1186/s12891-022-05994-3

[70] Initial fixation and cyclic loading stability of knotless suture anchors for rotator cuff repair. Journal of Shoulder and Elbow Surgery. 2008. DOI: 10.1016/j.jse.2007.05.016

[71] Clinical and Radiographic Results of an All-Polyethylene Pegged Bone-Ingrowth Glenoid Component. Journal of Bone and Joint Surgery. 2016. DOI: 10.2106/jbjs.15.00475

[72] Classifications in Brief: The Nerot-Sirveaux Classification for Scapular Notching. Clinical Orthopaedics & Related Research. 2018. DOI: 10.1097/corr.0000000000000442

[73] Comparative clinical and radiologic evaluation between patients undergoing standard reversed shoulder arthroplasty or bony increased offset. Clinics in Shoulder and Elbow. 2023. DOI: 10.5397/cise.2022.01270

[74] Modified Weaver-Dunn Technique Using Transosseous Bone Tunnels and Coracoid Suture Augmentation. Journal of the American Academy of Orthopaedic Surgeons. 2021. DOI: 10.5435/jaaos-d-21-00732

[76] The Incidence of Early Metallic Suture Anchor Pullout After Arthroscopic Rotator Cuff Repair. Arthroscopy. 2010. DOI: 10.1016/j.arthro.2009.08.015

[77] Shoulder Arthrodesis: Functional Outcome and Morbidity after Combined Plate/screw Fixation versus Screw Fixation Alone. Shoulder & Elbow. 2012. DOI: 10.1111/j.1758-5740.2011.00174.x

[78] All‐Arthroscopic Biologic Total Shoulder Resurfacing. Arthroscopy. 2011. DOI: 10.1016/j.arthro.2011.07.008

[79] Hepatitis C infection and complication rates after total shoulder arthroplasty in United States veterans. JSES International. 2021. DOI: 10.1016/j.jseint.2021.02.009

[80] Risk factors for periprosthetic infection after reverse shoulder arthroplasty. Journal of Shoulder and Elbow Surgery. 2015. DOI: 10.1016/j.jse.2014.05.020

[81] Mid- to long-term results after bipolar radial head arthroplasty. Journal of Shoulder and Elbow Surgery. 2010. DOI: 10.1016/j.jse.2010.05.022

[82] Direct-Exchange Arthroplasty for the Treatment of Infection after Total Hip Replacement. An Average Ten-Year Follow-up. The Journal of Bone & Joint Surgery*. 1998. DOI: 10.2106/00004623-199807000-00004

[83] Shoulder arthroplasty in patients 59 years of age and younger. Journal of Shoulder and Elbow Surgery. 2013. DOI: 10.1016/j.jse.2013.01.029

Creative Commons BY-NC 4.0

CC Creative Commons licence
BY Attribution — you must credit the source
NC NonCommercial — not for commercial use

Attribution-NonCommercial 4.0 International


Creative Commons Corporation ("Creative Commons") is not a law firm and does not provide legal services or legal advice. Distribution of Creative Commons public licenses does not create a lawyer-client or other relationship. Creative Commons makes its licenses and related information available on an "as-is" basis. Creative Commons gives no warranties regarding its licenses, any material licensed under their terms and conditions, or any related information. Creative Commons disclaims all liability for damages resulting from their use to the fullest extent possible.

Using Creative Commons Public Licenses

Creative Commons public licenses provide a standard set of terms and conditions that creators and other rights holders may use to share original works of authorship and other material subject to copyright and certain other rights specified in the public license below. The following considerations are for informational purposes only, are not exhaustive, and do not form part of our licenses.

Considerations for licensors: Our public licenses are intended for use by those authorized to give the public permission to use material in ways otherwise restricted by copyright and certain other rights. Our licenses are irrevocable. Licensors should read and understand the terms and conditions of the license they choose before applying it. Licensors should also secure all rights necessary before applying our licenses so that the public can reuse the material as expected. Licensors should clearly mark any material not subject to the license. This includes other CC- licensed material, or material used under an exception or limitation to copyright. More considerations for licensors: wiki.creativecommons.org/Considerations_for_licensors

Considerations for the public: By using one of our public licenses, a licensor grants the public permission to use the licensed material under specified terms and conditions. If the licensor's permission is not necessary for any reason--for example, because of any applicable exception or limitation to copyright--then that use is not regulated by the license. Our licenses grant only permissions under copyright and certain other rights that a licensor has authority to grant. Use of the licensed material may still be restricted for other reasons, including because others have copyright or other rights in the material. A licensor may make special requests, such as asking that all changes be marked or described. Although not required by our licenses, you are encouraged to respect those requests where reasonable. More considerations for the public: wiki.creativecommons.org/Considerations_for_licensees


Creative Commons Attribution-NonCommercial 4.0 International Public License

By exercising the Licensed Rights (defined below), You accept and agree to be bound by the terms and conditions of this Creative Commons Attribution-NonCommercial 4.0 International Public License ("Public License"). To the extent this Public License may be interpreted as a contract, You are granted the Licensed Rights in consideration of Your acceptance of these terms and conditions, and the Licensor grants You such rights in consideration of benefits the Licensor receives from making the Licensed Material available under these terms and conditions.

Section 1 -- Definitions.

a. Adapted Material means material subject to Copyright and Similar Rights that is derived from or based upon the Licensed Material and in which the Licensed Material is translated, altered, arranged, transformed, or otherwise modified in a manner requiring permission under the Copyright and Similar Rights held by the Licensor. For purposes of this Public License, where the Licensed Material is a musical work, performance, or sound recording, Adapted Material is always produced where the Licensed Material is synched in timed relation with a moving image.

b. Adapter's License means the license You apply to Your Copyright and Similar Rights in Your contributions to Adapted Material in accordance with the terms and conditions of this Public License.

c. Copyright and Similar Rights means copyright and/or similar rights closely related to copyright including, without limitation, performance, broadcast, sound recording, and Sui Generis Database Rights, without regard to how the rights are labeled or categorized. For purposes of this Public License, the rights specified in Section 2(b)(1)-(2) are not Copyright and Similar Rights.

d. Effective Technological Measures means those measures that, in the absence of proper authority, may not be circumvented under laws fulfilling obligations under Article 11 of the WIPO Copyright Treaty adopted on December 20, 1996, and/or similar international agreements.

e. Exceptions and Limitations means fair use, fair dealing, and/or any other exception or limitation to Copyright and Similar Rights that applies to Your use of the Licensed Material.

f. Licensed Material means the artistic or literary work, database, or other material to which the Licensor applied this Public License.

g. Licensed Rights means the rights granted to You subject to the terms and conditions of this Public License, which are limited to all Copyright and Similar Rights that apply to Your use of the Licensed Material and that the Licensor has authority to license.

h. Licensor means the individual(s) or entity(ies) granting rights under this Public License.

i. NonCommercial means not primarily intended for or directed towards commercial advantage or monetary compensation. For purposes of this Public License, the exchange of the Licensed Material for other material subject to Copyright and Similar Rights by digital file-sharing or similar means is NonCommercial provided there is no payment of monetary compensation in connection with the exchange.

j. Share means to provide material to the public by any means or process that requires permission under the Licensed Rights, such as reproduction, public display, public performance, distribution, dissemination, communication, or importation, and to make material available to the public including in ways that members of the public may access the material from a place and at a time individually chosen by them.

k. Sui Generis Database Rights means rights other than copyright resulting from Directive 96/9/EC of the European Parliament and of the Council of 11 March 1996 on the legal protection of databases, as amended and/or succeeded, as well as other essentially equivalent rights anywhere in the world.

l. You means the individual or entity exercising the Licensed Rights under this Public License. Your has a corresponding meaning.

Section 2 -- Scope.

a. License grant.

1. Subject to the terms and conditions of this Public License, the Licensor hereby grants You a worldwide, royalty-free, non-sublicensable, non-exclusive, irrevocable license to exercise the Licensed Rights in the Licensed Material to:

a. reproduce and Share the Licensed Material, in whole or in part, for NonCommercial purposes only; and

b. produce, reproduce, and Share Adapted Material for NonCommercial purposes only.

2. Exceptions and Limitations. For the avoidance of doubt, where Exceptions and Limitations apply to Your use, this Public License does not apply, and You do not need to comply with its terms and conditions.

3. Term. The term of this Public License is specified in Section 6(a).

4. Media and formats; technical modifications allowed. The Licensor authorizes You to exercise the Licensed Rights in all media and formats whether now known or hereafter created, and to make technical modifications necessary to do so. The Licensor waives and/or agrees not to assert any right or authority to forbid You from making technical modifications necessary to exercise the Licensed Rights, including technical modifications necessary to circumvent Effective Technological Measures. For purposes of this Public License, simply making modifications authorized by this Section 2(a) (4) never produces Adapted Material.

5. Downstream recipients.

a. Offer from the Licensor -- Licensed Material. Every recipient of the Licensed Material automatically receives an offer from the Licensor to exercise the Licensed Rights under the terms and conditions of this Public License.

b. No downstream restrictions. You may not offer or impose any additional or different terms or conditions on, or apply any Effective Technological Measures to, the Licensed Material if doing so restricts exercise of the Licensed Rights by any recipient of the Licensed Material.

6. No endorsement. Nothing in this Public License constitutes or may be construed as permission to assert or imply that You are, or that Your use of the Licensed Material is, connected with, or sponsored, endorsed, or granted official status by, the Licensor or others designated to receive attribution as provided in Section 3(a)(1)(A)(i).

b. Other rights.

1. Moral rights, such as the right of integrity, are not licensed under this Public License, nor are publicity, privacy, and/or other similar personality rights; however, to the extent possible, the Licensor waives and/or agrees not to assert any such rights held by the Licensor to the limited extent necessary to allow You to exercise the Licensed Rights, but not otherwise.

2. Patent and trademark rights are not licensed under this Public License.

3. To the extent possible, the Licensor waives any right to collect royalties from You for the exercise of the Licensed Rights, whether directly or through a collecting society under any voluntary or waivable statutory or compulsory licensing scheme. In all other cases the Licensor expressly reserves any right to collect such royalties, including when the Licensed Material is used other than for NonCommercial purposes.

Section 3 -- License Conditions.

Your exercise of the Licensed Rights is expressly made subject to the following conditions.

a. Attribution.

1. If You Share the Licensed Material (including in modified form), You must:

a. retain the following if it is supplied by the Licensor with the Licensed Material:

i. identification of the creator(s) of the Licensed Material and any others designated to receive attribution, in any reasonable manner requested by the Licensor (including by pseudonym if designated);

ii. a copyright notice;

iii. a notice that refers to this Public License;

iv. a notice that refers to the disclaimer of warranties;

v. a URI or hyperlink to the Licensed Material to the extent reasonably practicable;

b. indicate if You modified the Licensed Material and retain an indication of any previous modifications; and

c. indicate the Licensed Material is licensed under this Public License, and include the text of, or the URI or hyperlink to, this Public License.

2. You may satisfy the conditions in Section 3(a)(1) in any reasonable manner based on the medium, means, and context in which You Share the Licensed Material. For example, it may be reasonable to satisfy the conditions by providing a URI or hyperlink to a resource that includes the required information.

3. If requested by the Licensor, You must remove any of the information required by Section 3(a)(1)(A) to the extent reasonably practicable.

4. If You Share Adapted Material You produce, the Adapter's License You apply must not prevent recipients of the Adapted Material from complying with this Public License.

Section 4 -- Sui Generis Database Rights.

Where the Licensed Rights include Sui Generis Database Rights that apply to Your use of the Licensed Material:

a. for the avoidance of doubt, Section 2(a)(1) grants You the right to extract, reuse, reproduce, and Share all or a substantial portion of the contents of the database for NonCommercial purposes only;

b. if You include all or a substantial portion of the database contents in a database in which You have Sui Generis Database Rights, then the database in which You have Sui Generis Database Rights (but not its individual contents) is Adapted Material; and

c. You must comply with the conditions in Section 3(a) if You Share all or a substantial portion of the contents of the database.

For the avoidance of doubt, this Section 4 supplements and does not replace Your obligations under this Public License where the Licensed Rights include other Copyright and Similar Rights.

Section 5 -- Disclaimer of Warranties and Limitation of Liability.

a. UNLESS OTHERWISE SEPARATELY UNDERTAKEN BY THE LICENSOR, TO THE EXTENT POSSIBLE, THE LICENSOR OFFERS THE LICENSED MATERIAL AS-IS AND AS-AVAILABLE, AND MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND CONCERNING THE LICENSED MATERIAL, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHER. THIS INCLUDES, WITHOUT LIMITATION, WARRANTIES OF TITLE, MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, NON-INFRINGEMENT, ABSENCE OF LATENT OR OTHER DEFECTS, ACCURACY, OR THE PRESENCE OR ABSENCE OF ERRORS, WHETHER OR NOT KNOWN OR DISCOVERABLE. WHERE DISCLAIMERS OF WARRANTIES ARE NOT ALLOWED IN FULL OR IN PART, THIS DISCLAIMER MAY NOT APPLY TO YOU.

b. TO THE EXTENT POSSIBLE, IN NO EVENT WILL THE LICENSOR BE LIABLE TO YOU ON ANY LEGAL THEORY (INCLUDING, WITHOUT LIMITATION, NEGLIGENCE) OR OTHERWISE FOR ANY DIRECT, SPECIAL, INDIRECT, INCIDENTAL, CONSEQUENTIAL, PUNITIVE, EXEMPLARY, OR OTHER LOSSES, COSTS, EXPENSES, OR DAMAGES ARISING OUT OF THIS PUBLIC LICENSE OR USE OF THE LICENSED MATERIAL, EVEN IF THE LICENSOR HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH LOSSES, COSTS, EXPENSES, OR DAMAGES. WHERE A LIMITATION OF LIABILITY IS NOT ALLOWED IN FULL OR IN PART, THIS LIMITATION MAY NOT APPLY TO YOU.

c. The disclaimer of warranties and limitation of liability provided above shall be interpreted in a manner that, to the extent possible, most closely approximates an absolute disclaimer and waiver of all liability.

Section 6 -- Term and Termination.

a. This Public License applies for the term of the Copyright and Similar Rights licensed here. However, if You fail to comply with this Public License, then Your rights under this Public License terminate automatically.

b. Where Your right to use the Licensed Material has terminated under Section 6(a), it reinstates:

1. automatically as of the date the violation is cured, provided it is cured within 30 days of Your discovery of the violation; or

2. upon express reinstatement by the Licensor.

For the avoidance of doubt, this Section 6(b) does not affect any right the Licensor may have to seek remedies for Your violations of this Public License.

c. For the avoidance of doubt, the Licensor may also offer the Licensed Material under separate terms or conditions or stop distributing the Licensed Material at any time; however, doing so will not terminate this Public License.

d. Sections 1, 5, 6, 7, and 8 survive termination of this Public License.

Section 7 -- Other Terms and Conditions.

a. The Licensor shall not be bound by any additional or different terms or conditions communicated by You unless expressly agreed.

b. Any arrangements, understandings, or agreements regarding the Licensed Material not stated herein are separate from and independent of the terms and conditions of this Public License.

Section 8 -- Interpretation.

a. For the avoidance of doubt, this Public License does not, and shall not be interpreted to, reduce, limit, restrict, or impose conditions on any use of the Licensed Material that could lawfully be made without permission under this Public License.

b. To the extent possible, if any provision of this Public License is deemed unenforceable, it shall be automatically reformed to the minimum extent necessary to make it enforceable. If the provision cannot be reformed, it shall be severed from this Public License without affecting the enforceability of the remaining terms and conditions.

c. No term or condition of this Public License will be waived and no failure to comply consented to unless expressly agreed to by the Licensor.

d. Nothing in this Public License constitutes or may be interpreted as a limitation upon, or waiver of, any privileges and immunities that apply to the Licensor or You, including from the legal processes of any jurisdiction or authority.


Creative Commons is not a party to its public licenses. Notwithstanding, Creative Commons may elect to apply one of its public licenses to material it publishes and in those instances will be considered the “Licensor.” The text of the Creative Commons public licenses is dedicated to the public domain under the CC0 Public Domain Dedication. Except for the limited purpose of indicating that material is shared under a Creative Commons public license or as otherwise permitted by the Creative Commons policies published at creativecommons.org/policies, Creative Commons does not authorize the use of the trademark "Creative Commons" or any other trademark or logo of Creative Commons without its prior written consent including, without limitation, in connection with any unauthorized modifications to any of its public licenses or any other arrangements, understandings, or agreements concerning use of licensed material. For the avoidance of doubt, this paragraph does not form part of the public licenses.

Creative Commons may be contacted at creativecommons.org.